  Datasheet File OCR Text:
 AOZ1210-EVA
EZBuckTM 2A Simple Buck Regulator Evaluation Board Note
General Description
The AOZ1210 evaluation board is a fully assembled and tested circuit board built with the AOZ1210 buck regulator IC. It outputs a preset or adjustable voltage at up to 2A of continuous current. The evaluation board requires an input voltage from 4.5V to 27V. The output voltage is preset and can be adjusted. The AOZ1210-EVA circuit has features like current limit, short circuit protection, input under voltage lock out, internal soft start and thermal shut down. The current mode control and integrated internal MOSFET minimize component count, board area and total cost. The AOZ1210 comes in an SO-8 package and is rated over a -40C to +85C ambient temperature range.
Features


4.5V to 27V operating input voltage range Output voltage is preset to 3.3V, adjustable down to 0.8V 2A continuous output current Internal soft start Cycle-by-cycle current limit Short-circuit protection Thermal shutdown
Applications

Point of load DC/DC conversion PCIe graphics cards Set top boxes DVD drives and HDD LCD panels Cable modems Telecom/networking/datacom equipment
Evaluation Board Schematic
C7
C8
C1 R3
VIN EN
C6
BS
L1
VOUT LX
AOZ1210
VBIAS
C4
R1
FB GND
R2
C2
C3
COMP
CC RC
Rev. 1.0 December 2007
www.aosmd.com
Page 1 of 5
AOZ1210-EVA
BOM of 5V/2A AOZ1210 Regulator
Ref Designation
C1 C2 C3 C4 C5 C6 C7 C8 CC * RC* R1* R2 R3 L1* D1 U1 AOZ1210A
Value
10F 22F 22F 1F NC 1F 0.1F 10F 2000pF 5k 31.6k 10k 0k 6.8H
Description
Ceramic Cap, 50V, X7R/X7R Ceramic Cap, 25V, X7R/X5R Ceramic Cap, 25V, X7R/X5R Ceramic Cap, 25V, X7R/X5R Ceramic Cap, 50V, X7R Ceramic Cap, 50V, X7R Ceramic Cap, 50V, X7R/X7R Ceramic Cap, 50V, X7R Thick Film Res, 1% Thick Film Res, 1% Thick Film Res, 1% Thick Film Res, 1% MSS1260 40V diode, B340B-13 Buck regulator IC
Package
1210 1210 1210 0603 0603 0603 1210 0603 0603 0603 0603 0603
Manufacturer
Murata, AVX
DALE
Murata SMB SO-8 Diodes AOS
VO is set by R1, (R2 = 10k), R1 = (10 x VO-8) / 0.8k *Value may change for different output values.
Rev. 1.0 December 2007
www.aosmd.com
Page 2 of 5
AOZ1210-EVA
PCB Layout
Figure 1. Top Silk Screen
Figure 2. Top Layer
Rev. 1.0 December 2007
www.aosmd.com
Page 3 of 5
AOZ1210-EVA
Figure 3. Bottom Layer
Quick Start Guide
1. Connect the terminals of load to +VOUT pins and GND pins. Set load current to between 0A and 2A. 2. Connect the DC power supply to +VIN pin and GND pins. Set DC power supply voltage to between 4.5V and 27V. 3. Connect EN pin to +VIN or any voltage source which is between 2.5V and 27V. 4. Turn on DC power supply and evaluation circuit will start. 5. Measure input voltage at the +VIN pin and GND pins to eliminate the effect of voltage drop on wire between DC power supply and evaluation board. 6. Measure output voltage at the +VOUT pin and GND pins to eliminate the effect of the voltage drop on wire between load and evaluation board. 7. Use an oscilloscope to monitor input ripple voltage right across input capacitor C1. 8. Use an oscilloscope to monitor output ripple voltage right across output capacitor C2.
Rev. 1.0 December 2007
www.aosmd.com
Page 4 of 5
AOZ1210-EVA
This data sheet contains preliminary data; supplementary data may be published at a later date. Alpha & Omega Semiconductor reserves the right to make changes at any time without notice. LIFE SUPPORT POLICY ALPHA & OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Rev. 1.0 December 2007
www.aosmd.com
Page 5 of 5


▲Up To Search▲   

 
Price & Availability of AOZ1210-EVA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X